{"id":12044,"date":"2022-07-24T11:04:49","date_gmt":"2022-07-24T02:04:49","guid":{"rendered":"http:\/\/ftz.myds.me\/wordpress\/?p=12044"},"modified":"2022-07-27T15:36:06","modified_gmt":"2022-07-27T06:36:06","slug":"%ea%b8%b0%ec%88%a0%ea%b8%b0%ec%a4%80-1-7","status":"publish","type":"post","link":"http:\/\/ftz.myds.me\/wordpress\/%ea%b8%b0%ec%88%a0%ea%b8%b0%ec%a4%80-1-7\/","title":{"rendered":"\uae30\uc220\uae30\uc900 1.7 \uad6d\uc81c\ud45c\uc900\ub3c4\uc785\u25cf"},"content":{"rendered":"\n<h2>\uc804\uae30\uc124\ube44 \uc81c7\uc7a5 \uad6d\uc81c\ud45c\uc900\ub3c4\uc785<\/h2>\n\n\n\n<h6> <a href=\"http:\/\/ftz.myds.me\/wordpress\/%EA%B8%B0%EC%88%A0%EA%B8%B0%EC%A4%80-1-7\/#\uc81c279\uc870\">\uc81c279\uc870<\/a>,  <a href=\"http:\/\/ftz.myds.me\/wordpress\/%EA%B8%B0%EC%88%A0%EA%B8%B0%EC%A4%80-1-7\/#\uc81c280\uc870\">\uc81c280\uc870<\/a>, <\/h6>\n\n\n\n<h4 id=\"\uc81c279\uc870\">\uc81c279\uc870(1 kV \uc774\ud558 \uc804\uae30\uc124\ube44\uc758 \uc2dc\uc124) <\/h4>\n\n\n\n<p>\u2460 \uc218\uc6a9 \uc7a5\uc18c\uc5d0 \uc2dc\uc124\ud558\ub294 1kV \uc774\ud558 \uc804\uae30\uc124\ube44\ub294 \ud45c 279-1\uc758 IEC 60364\uc5d0 \ub530\ub77c \uc2dc\uc124\ud560 \uc218 \uc788\ub2e4. \ub2e4\ub9cc, \uc804\uae30\uc0ac\uc5c5\uc790\uc758 \uc804\uae30\uc124\ube44\uc640 \uc9c1\uc811 \uc811\uc18d\ud558\ub294 \uacbd\uc6b0\uc5d0\ub294 \uc804\uae30\uc0ac\uc5c5\uc790\uc758 \uc804\uae30\uacf5\uae09\uacfc \uad00\ub828\ub41c \uc124\ube44\uc758 \uc811\uc9c0\ubc29\uc2dd\uacfc \ud611\uc870\ub97c \uc774\ub8e8\uc5b4\uc57c \ud55c\ub2e4.<\/p>\n\n\n\n<p>\u2461 \ub3d9\uc77c\ud55c \uc804\uae30\uc0ac\uc6a9\uc7a5\uc18c\uc5d0\uc11c\ub294 \uc81c1\ud56d\uc758 \uaddc\uc815\uacfc \uc81c3\uc870\ubd80\ud130 \uc81c278\uc870\uae4c\uc9c0\uc758 \uaddc\uc815\uc744 \ud63c\uc6a9\ud558\uc5ec 1kV \uc774\ud558\uc758 \uc804\uae30\uc124\ube44\ub97c \uc2dc\uc124\ud558\uc5ec\uc11c\ub294 \uc544\ub2c8 \ub41c\ub2e4. \ub2e4\ub9cc, IEC \ud45c\uc900\uc744 \ub3c4\uc785\ud55c \uc870\ud56d\uc740 \uc608\uc678\ub85c \ud55c\ub2e4.<\/p>\n\n\n\n<p>&nbsp; [\ud45c 279-1]<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>IEC\ud45c\uc900\ubc88\ud638(\uc81c\uc815\ub144\ub3c4)<\/td><td>KS\ud45c\uc900\ubc88\ud638(\uc81c\uc815\ub144\ub3c4)<\/td><td>\uaddc&nbsp; \uaca9&nbsp; \uba85<\/td><\/tr><tr><td>IEC 60364-1(2001) (\ub2e4\ub9cc, 313.2\ub97c \uc81c\uc678\ud55c\ub2e4)<\/td><td>KS C IEC 60364-1(2005) (\ub2e4\ub9cc, 313.2\ub97c \uc81c\uc678\ud55c\ub2e4)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c1\ubd80: \uae30\ubcf8\uc6d0\uce59, \uc77c\ubc18\ud2b9\uc131\ud3c9\uac00 \ubc0f \uc6a9\uc5b4\uc815\uc758<\/td><\/tr><tr><td>IEC 60364-4-41(2001)<\/td><td>KS C IEC 60364-4-41(2005)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c4 &#8211; \uc81c41\ubd80 : \uc548\uc804\uc744 \uc704\ud55c \ubcf4\ud638 &#8211; \uac10\uc804\uc5d0 \ub300\ud55c \ubcf4\ud638<\/td><\/tr><tr><td>IEC 60364-4-42(2001) (\ub2e4\ub9cc, 422.1, 422.2, 422.2.1, 422.2.2, 422.2.3, 422.3,&nbsp; 422.3.5, 422.3.6, 422.3.7, 422.5,&nbsp; 422.5.1\uc744 \uc81c\uc678\ud55c\ub2e4)<\/td><td>KS C IEC 60364-4-42(2005) (\ub2e4\ub9cc, 422.1, 422.2, 422.2.1, 422.2.2, 422.2.3, 422.3, 422.3.5, 422.3.6,&nbsp; 422.3.7, 422.5, 422.5.1\uc744 \uc81c\uc678\ud55c\ub2e4)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c4 &#8211; 42\ubd80 : \uc548\uc804\uc744 \uc704\ud55c \ubcf4\ud638 &#8211; \uc5f4 \uc601\ud5a5\uc5d0 \ub300\ud55c \ubcf4\ud638<\/td><\/tr><tr><td>IEC 60364-4-43(2001)<\/td><td>KS C IEC 60364-4-43(2005)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c4 &#8211; 43\ubd80 : \uc548\uc804\uc744 \uc704\ud55c \ubcf4\ud638 &#8211; \uacfc\uc804\ub958\uc5d0 \ub300\ud55c \ubcf4\ud638<\/td><\/tr><tr><td>IEC 60364-4-44(2001)\uc758&nbsp; 442<\/td><td>KS C IEC 60364-4-44(2005) \uc758 442<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c4 &#8211; 44\ubd80 \uc548\uc804\uc744 \uc704\ud55c \ubcf4\ud638 : \uc804\uc555 \ubc0f \uc804\uc790\ud30c\uc7a5\ud574\uc5d0 \ub300\ud55c \ubcf4\ud638 \uc81c442\uc808 : \uace0\uc555\uacc4\ud1b5\uacfc \uc811\uc9c0\uc0ac\uc774\uc758 \uc21c\uc2dc\uacfc\uc804\uc555 \ubc0f \uace0\uc7a5\uc5d0 \ub300\ud55c \uc800\uc555\uc124\ube44\uc758 \ubcf4\ud638<\/td><\/tr><tr><td>IEC 60364-5-51(2001)(\ub2e4\ub9cc,&nbsp; 515.3 \uc81c\uc678)<\/td><td>KS C IEC 60364-5-51(2005) (\ub2e4\ub9cc, 515.3 \uc81c\uc678)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c5 &#8211; \uc81c51\ubd80 : \uc804\uae30\uae30\uae30\uc758 \uc120\uc815 \ubc0f \uc2dc\uacf5 &#8211; \uacf5\ud1b5 \uaddc\uce59<\/td><\/tr><tr><td>IEC 60364-5-52(2001)<\/td><td>KS C IEC 60364-5-52(2004)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c5 &#8211; 52\ubd80 : \uc804\uae30\uae30\uae30\uc758 \uc120\uc815 \ubc0f \uc2dc\uacf5 &#8211; \ubc30\uc120\uc2dc\uc2a4\ud15c<\/td><\/tr><tr><td>IEC 60364-5-53(2002) (\ub2e8 534\uc808, 535\uc808 \uc81c\uc678)<\/td><td>KS C IEC 60364-5-53(2005) (\ub2e8 534\uc808, 535\uc808 \uc81c\uc678)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c5 &#8211; 53\ubd80 : \uc804\uae30\uae30\uae30\uc758 \uc120\uc815 \ubc0f \uc2dc\uacf5 &#8211; \uc808\uc5f0, \uac1c\ud3d0 \ubc0f \uc81c\uc5b4<\/td><\/tr><tr><td>IEC 60364-5-54(2002)<\/td><td>KS C IEC 60364-5-54(2005)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c5 &#8211; 54\ubd80 \uc804\uae30\uae30\uae30\uc758 \uc120\uc815 \ubc0f \uc2dc\uacf5 &#8211; \uc811\uc9c0\ubc30\uce58. \ubcf4\ud638\ub3c4\uccb4 \ubc0f \uacb0\ud569\ub3c4\uccb4<\/td><\/tr><tr><td>IEC 60364-5-55(2002) \uc758 551\uc808, 559\uc808<\/td><td>KS C IEC60364-5-55(2005)\uc758 551\uc808, 559\uc808<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c5 &#8211; \uc81c55\ubd80 \uc804\uae30\uae30\uae30\uc758 \uc120\uc815 \ubc0f \uc2dc\uacf5 &#8211; \uae30\ud0c0\uae30\uae30 \uc81c551\uc808 : \uc800\uc555\ubc1c\uc804\uc7a5\uce58, \uc81c559\uc808 : \uc870\uba85\uae30\uad6c \ubc0f \uc870\uba85\uc124\ube44<\/td><\/tr><tr><td>IEC 60364-6-61(2001)<\/td><td>KS C IEC 60364-6-61(2005)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c6 &#8211; 61\ubd80 \uac80\uc0ac &#8211; \ucd5c\ucd08 \uac80\uc0ac<\/td><\/tr><tr><td>IEC 60364-7-701(1984)<\/td><td>KS C IEC 60364-7-701(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c701\uc808 \uc695\uc870 \ub610\ub294 \uc0e4\uc6cc\uc695\uc870\uc758 \uc804\uae30\uc124\ube44<\/td><\/tr><tr><td>IEC 60364-7-702(1983) Amd.2(1997)<\/td><td>KS C IEC 60364-7-702(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c702\uc808 \uc218\uc601\uc7a5 \ubc0f \uae30\ud0c0 \uc218\uc870<\/td><\/tr><tr><td>IEC 60364-7-703(1984)<\/td><td>KS C IEC 60364-7-703(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c703\uc808 \uc0ac\uc6b0\ub098\ud788\ud130\uc758 \uc804\uae30\uc124\ube44<\/td><\/tr><tr><td>IEC 60364-7-704(1999)<\/td><td>KS C IEC 60364-7-704(2005)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7 &#8211; 704\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uac74\uc124\ud604\uc7a5 \ubc0f \ud574\uccb4\ud604\uc7a5\uc5d0\uc11c\uc758 \uc124\ube44<\/td><\/tr><tr><td>IEC 60364-7-705(1984)<\/td><td>KS C IEC 60364-7-705(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c705\uc808 \ub18d\uc5c5 \ubc0f \uc6d0\uc608\uc6a9 \uc804\uae30\uc124\ube44<\/td><\/tr><tr><td>IEC 60364-7-706(1983)<\/td><td>KS C IEC 60364-7-706(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c706\uc808 \uc81c\ud55c\ub41c \ub3c4\uc804\uc131 \uc7a5\uc18c<\/td><\/tr><tr><td>IEC 60364-7-707(1984)<\/td><td>KS C IEC 60364-7-707(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c707\uc808 \ub370\uc774\ud130 \ucc98\ub9ac\uae30\uae30\uc124\ube44\uc758 \uc811\uc9c0<\/td><\/tr><tr><td>IEC 60364-7-708(1988) Amd.1(1993)<\/td><td>KS C IEC 60364-7-708(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c708\uc808 \uc774\ub3d9\uc2dd \uc219\ubc15\ucc28\ub7c9 \ubc0f \uc815\ubc15\uc9c0\uc758 \uc804\uae30\uc124\ube44<\/td><\/tr><tr><td>IEC 60364-7-709(1994)<\/td><td>KS C IEC 60364-7-709(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c709\uc808 \ub9c8\ub9ac\ub098 \ubc0f \ub808\uc800\uc6a9 \uc120\ubc15\uc758 \uc804\uae30\uc124\ube44<\/td><\/tr><tr><td>IEC 60364-7-710(2002)<\/td><td>KS C IEC 60364-7-710(2005)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7 &#8211; 710\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218\uc7a5\uc18c\uc5d0 \ub300\ud55c \uc694\uad6c\uc0ac\ud56d &#8211; \uc758\ub8cc\uc7a5\uc18c<\/td><\/tr><tr><td>IEC 60364-7-711(1998)<\/td><td>KS C IEC 60364-7-711(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218 \uc7a5\uc18c\uc758 \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c711\uc808 \uc804\uc2dc\ud68c, \uc1fc \ubc0f \uacf5\uc5f0\uc7a5\uc758 \uc804\uae30\uc124\ube44<\/td><\/tr><tr><td>IEC 60364-7-712(2002)<\/td><td>KS C IEC 60364-7-712(2005)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7 &#8211; 712\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294&nbsp; \ud2b9\uc218\uc7a5\uc18c\uc5d0 \ub300\ud55c \uc694\uad6c\uc0ac\ud56d &#8211; \ud0dc\uc591\uc804\uc9c0(PV) \uc804\uc6d0 \uc2dc\uc2a4\ud15c<\/td><\/tr><tr><td>IEC 60364-7-714(1996)<\/td><td>KS C IEC 60364-7-714(2002)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218\uc7a5\uc18c\uc758&nbsp; \uc694\uad6c\uc0ac\ud56d &#8211; \uc81c714\uc808 \uc625\uc678\uc870\uba85\uc6a9 \uc804\uae30\uc124\ube44<\/td><\/tr><tr><td>IEC 60364-7-715(1995)<\/td><td>KS C IEC 60364-7-715(2003)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7 &#8211; 715\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218\uc7a5\uc18c\uc5d0 \ub300\ud55c \uc694\uad6c\uc0ac\ud56d &#8211; \ucd08\uc800\uc555 \uc870\uba85\uc124\ube44<\/td><\/tr><tr><td>IEC 60364-7-717(2001)<\/td><td>KS C IEC 60364-7-717(2004)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7 &#8211; 717\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218\uc7a5\uc18c\uc5d0 \ub300\ud55c \uc694\uad6c\uc0ac\ud56d &#8211; \uc774\ub3d9\uc2dd \ub610\ub294 \uc6b4\ubc18\uc2dd \uc7a5\uce58<\/td><\/tr><tr><td>IEC 60364-7-740(2000)<\/td><td>KS C IEC 60364-7-740(2004)<\/td><td>\uac74\ucd95\uc804\uae30\uc124\ube44 &#8211; \uc81c7 &#8211; 740\ubd80 \ud2b9\uc218\uc124\ube44 \ub610\ub294 \ud2b9\uc218\uc7a5\uc18c\uc5d0 \ub300\ud55c \uc694\uad6c\uc0ac\ud56d &#8211;&nbsp; \ubc15\ub78c\ud68c, \uc720\uc6d0\uc9c0 \ubc0f \uc11c\ucee4\uc2a4 \uc7a5\uc18c\uc758 \uad6c\uc870\ubb3c, \uc624\ub77d\uc7a5\uce58 \ubc0f \ubd80\uc2a4\uc6a9 \uc784\uc2dc \uc804\uae30\uc124\ube44<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h6>\ube44\uace0 : \uc774 \ud45c \uc911\uc5d0\uc11c \uc801\uc6a9\uc774 \uc81c\uc678\ub41c \ud45c\uc900\uc740 \ud45c \uc911\uc758 \ud45c\uc900\uc5d0\uc11c \uc778\uc6a9\ub41c \uacbd\uc6b0\uc5d0\ub3c4 \uc801\uc6a9\uc774 \uc81c\uc678\ub41c\ub2e4.<\/h6>\n\n\n\n<h4 id=\"\uc81c280\uc870\">\uc81c280\uc870(1 kV \ucd08\uacfc \uc804\uae30\uc124\ube44\uc758 \uc2dc\uc124) <\/h4>\n\n\n\n<p>\u2460 1kV \ucd08\uacfc \uc804\uae30\uc124\ube44(\uc218\uc6a9\uc7a5\uc18c \uc774\uc678\uc5d0 \uc2dc\uc124\ud558\ub294 \uc804\uc120\ub85c\ub294 \uc81c\uc678\ud55c\ub2e4)\ub294 \ud45c 280-1\uc758 IEC 61936-1(2010)\uc5d0 \ub530\ub77c \uc2dc\uc124\ud560 \uc218 \uc788\ub2e4. \ub2e4\ub9cc, \ud45c 280-1\uc5d0\uc11c IEC \ud45c\uc900\uc5d0 \ub300\uc751\ud558\ub294 \ud310\ub2e8\uae30\uc900\uc774 \ud45c\uae30\ub41c \uac83\uc740 \uc81c3\uc870\ubd80\ud130 \uc81c278\uc870\uae4c\uc9c0\uc758 \ud574\ub2f9 \uaddc\uc815\uc5d0 \ub530\ub77c \uc2dc\uc124\ud558\uc5ec\uc57c \ud55c\ub2e4.<\/p>\n\n\n\n<p>\u2461 \ub3d9\uc77c\ud55c \ucd9c\uc785\uc81c\ud55c \uc804\uae30\uc6b4\uc804\uad6c\uc5ed\uc5d0\uc11c\ub294 \uc81c1\ud56d \ub2e8\uc11c\ub97c \uc81c\uc678\ud558\uace0 IEC 61936-1\uacfc \uc81c3\uc870\ubd80\ud130 \uc81c278\uc870\uae4c\uc9c0\uc758 \uaddc\uc815\uc744&nbsp; \ud63c\uc6a9\ud558\uc5ec \uc2dc\uc124\ud558\uc5ec\uc11c\ub294 \uc544\ub2c8 \ub41c\ub2e4. \ub2e4\ub9cc, IEC \ud45c\uc900\uc744 \uc801\uc6a9\ud55c \uc870\ud56d\uc740 \uc608\uc678\ub85c \ud55c\ub2e4.<\/p>\n\n\n\n<p>\u2462 \uc81c1\ud56d\uc5d0 \ub530\ub77c \uc2dc\uc124\ud558\ub294 1kV \ucd08\uacfc \uc804\uae30\uc124\ube44\uc5d0 1kV \uc774\ud558 \uc804\uae30\uc124\ube44\ub97c \uc811\uc18d\ud560 \uacbd\uc6b0 \uace0\uc7a5\uc2dc \ubc1c\uc0dd\ud558\ub294 \uacfc\uc804\uc555\uc5d0 \uc758\ud574 1kV \uc774\ud558 \uc804\uae30\uc124\ube44\uc5d0 \uc704\ud5d8\uc758 \uc6b0\ub824\uac00 \uc5c6\ub3c4\ub85d \uc2dc\uc124\ud558\uc5ec\uc57c \ud55c\ub2e4.<\/p>\n\n\n\n<p>&nbsp;&nbsp; [\ud45c 280-1]&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>IEC 61936-1<\/td><td>\ub300\uc751\ud558\ub294 \ud310\ub2e8\uae30\uc900<\/td><\/tr><tr><td>1 Scope<\/td><td>&#8211;<\/td><\/tr><tr><td>3 Terms and Definitions<\/td><td>&#8211;<\/td><\/tr><tr><td>4 Fundamental requirements<\/td><td>&#8211;<\/td><\/tr><tr><td>4.1 General<\/td><td>&#8211;<\/td><\/tr><tr><td>4.2 Electrical requirements<\/td><td>&#8211;<\/td><\/tr><tr><td>4.2.1 Methods of neutral earthing<\/td><td>&#8211;<\/td><\/tr><tr><td>4.2.2 Voltage classification<\/td><td>\uc81c13\uc870(\uc804\ub85c\uc758 \uc808\uc5f0\uc800\ud56d \ubc0f \uc808\uc5f0\ub0b4\ub825) \uc81c14\uc870(\ud68c\uc804\uae30 \ubc0f \uc815\ub958\uae30\uc758 \uc808\uc5f0\ub0b4\ub825) \uc81c15\uc870(\uc5f0\ub8cc\uc804\uc9c0 \ubc0f \ud0dc\uc591\uc804\uc9c0 \ubaa8\ub4c8\uc758 \uc808\uc5f0\ub0b4\ub825) \uc81c16\uc870(\ubcc0\uc555\uae30 \uc804\ub85c\uc758 \uc808\uc5f0\ub0b4\ub825) \uc81c17\uc870(\uae30\uad6c \ub4f1\uc758 \uc804\ub85c\uc758 \uc808\uc5f0\ub0b4\ub825)<\/td><\/tr><tr><td>4.2.3 Current in normal operation<\/td><td>&#8211;<\/td><\/tr><tr><td>4.2.4 Short-circuit current<\/td><td>&#8211;<\/td><\/tr><tr><td>4.2.5 Rated frequency<\/td><td>&#8211;<\/td><\/tr><tr><td>4.2.6 Corona (\u203b1)<\/td><td>\uc81c57\uc870(\uc804\ud30c \uc7a5\ud574\uc758 \ubc29\uc9c0)<\/td><\/tr><tr><td>4.2.7 Electric and magnetic fields<\/td><td>&#8211;<\/td><\/tr><tr><td>4.2.8 Overvoltages<\/td><td>\uc81c42\uc870(\ud53c\ub8b0\uae30\uc758 \uc2dc\uc124)<\/td><\/tr><tr><td>4.2.9 Harmonics<\/td><td>&#8211;<\/td><\/tr><tr><td>4.3 Mechanical requirements<\/td><td>\uc81c54\uc870\uc81c2\ud56d(\ud0dc\uc591\uc804\uc9c0 \ubaa8\ub4c8 \ub4f1\uc758 \uc2dc\uc124) \uc81c62\uc870(\ud48d\uc555\ud558\uc911\uc758 \uc885\ubcc4\uacfc \uc801\uc6a9)<\/td><\/tr><tr><td>4.4 Climatic and environmental conditions<\/td><td>&#8211;<\/td><\/tr><tr><td>4.4.1 General<\/td><td>\uc81c62\uc870(\ud48d\uc555\ud558\uc911\uc758 \uc885\ubcc4\uacfc \uc801\uc6a9) \uc81c71\uc870(\uc800\uace0\uc555 \uac00\uacf5\uc804\uc120\uc758 \uc548\uc804\uc728) \uc81c164\uc870(\ubb34\uc120\uc6a9 \uc548\ud14c\ub098 \ub4f1\uc744 \uc9c0\uc9c0\ud558\ub294 \ucca0\ud0d1 \ub4f1\uc758 \uc2dc\uc124) \uc81c200\uc870(\uac00\uc5f0\uc131 \uac00\uc2a4 \ub4f1\uc774 \uc788\ub294 \uacf3\uc758 \uc800\uc555\uc758 \uc2dc\uc124)<\/td><\/tr><tr><td>4.4.2 Normal conditions (\u203b2, \u203b3)<\/td><td><\/td><\/tr><tr><td>\uc81c62\uc870(\ud48d\uc555\ud558\uc911\uc758 \uc885\ubcc4\uacfc \uc801\uc6a9) \uc81c71\uc870(\uc800\uace0\uc555 \uac00\uacf5\uc804\uc120\uc758 \uc548\uc804\uc728) \uc81c164\uc870(\ubb34\uc120\uc6a9 \uc548\ud14c\ub098 \ub4f1\uc744 \uc9c0\uc9c0\ud558\ub294 \ucca0\ud0d1 \ub4f1\uc758 \uc2dc\uc124)<\/td><td><\/td><\/tr><tr><td>\uc81c200\uc870(\uac00\uc5f0\uc131 \uac00\uc2a4 \ub4f1\uc774 \uc788\ub294 \uacf3\uc758 \uc800\uc555\uc758 \uc2dc\uc124)4.4.3 Special conditions (\u203b2)<\/td><td>&#8211;<\/td><\/tr><tr><td>4.5 Special requirements<\/td><td>&#8211;<\/td><\/tr><tr><td>4.5.1 Effects of small animals and micro-organisms<\/td><td>&#8211;<\/td><\/tr><tr><td>4.5.2 Noise level (\u203b4)<\/td><td>&#8211;<\/td><\/tr><tr><td>5 Insulation<\/td><td>&#8211;<\/td><\/tr><tr><td>5.1 General<\/td><td>&#8211;<\/td><\/tr><tr><td>5.2 Selection of installation level<\/td><td>&#8211;<\/td><\/tr><tr><td>5.3 Verification of withstand values<\/td><td>&#8211;<\/td><\/tr><tr><td>5.4 Minimum clearances of live parts<\/td><td>&#8211;<\/td><\/tr><tr><td>5.5 Minimum clearances between parts under special conditions<\/td><td>&#8211;<\/td><\/tr><tr><td>5.6 Tested connection zones<\/td><td>&#8211;<\/td><\/tr><tr><td>6. Equipment<\/td><td>&#8211;<\/td><\/tr><tr><td>6.1 General requirements<\/td><td>&#8211;<\/td><\/tr><tr><td>6.2 Specific requirements<\/td><td>&#8211;<\/td><\/tr><tr><td>6.2.1 Switching devices<\/td><td>\uc81c35\uc870(\uc544\ud06c\ub97c \ubc1c\uc0dd\ud558\ub294 \uae30\uad6c\uc758 \uc2dc\uc124)<\/td><\/tr><tr><td>6.2.2 Power transformers and reactors<\/td><td>&#8211;<\/td><\/tr><tr><td>6.2.3 Prefabricated type-tested switchgear<\/td><td>\uc81c52\uc870(\uac00\uc2a4\uc808\uc5f0\uae30\uae30 \ub4f1\uc758 \uc555\ub825\uc6a9\uae30\uc758 \uc2dc\uc124)\uc81c1\ud56d<\/td><\/tr><tr><td>6.2.4 Instrument transformers<\/td><td>&#8211;<\/td><\/tr><tr><td>6.2.5 Surge arresters<\/td><td>&#8211;<\/td><\/tr><tr><td>6.2.6 Capacitors<\/td><td>&#8211;<\/td><\/tr><tr><td>6.2.8 Insulators<\/td><td>&#8211;<\/td><\/tr><tr><td>6.2.9 Insulated cables<\/td><td>\uc81c9\uc870(\uace0\uc555\ucf00\uc774\ube14 \ubc0f \ud2b9\uace0\uc555\ucf00\uc774\ube14) \uc81c136\uc870(\uc9c0\uc911 \uc804\uc120\ub85c\uc758 \uc2dc\uc124) \uc81c137\uc870(\uc9c0\uc911\ud568\uc758 \uc2dc\uc124) \uc81c139\uc870(\uc9c0\uc911\uc804\uc120\uc758 \ud53c\ubcf5\uae08\uc18d\uccb4 \uc811\uc9c0) \uc81c140\uc870(\uc9c0\uc911 \uc57d\uc804\ub958\uc804\uc120\uc5d0\uc758 \uc720\ub3c4\uc7a5\ud574 \ubc29\uc9c0) \uc81c141\uc870(\uc9c0\uc911\uc804\uc120\uacfc \uc9c0\uc911 \uc57d\uc804\ub958\uc804\uc120 \ub4f1 \ub610\ub294 \uad00\uacfc\uc758 \uc811\uadfc \ub610\ub294 \uad50\ucc28) \uc81c142\uc870(\uc9c0\uc911\uc804\uc120 \uc0c1\ud638 \uac04\uc758 \uc811\uadfc \ub610\ub294 \uad50\ucc28) \uc81c151\uc870(\uc625\ub0b4\uc5d0 \uc2dc\uc124\ud558\ub294 \uc804\uc120\ub85c)\uc81c2\ud56d \uc81c209\uc870(\uace0\uc555 \uc625\ub0b4\ubc30\uc120 \ub4f1\uc758 \uc2dc\uc124)\uc81c1\ud56d, \uc81c2\ud56d \uc81c210\uc870(\uc625\ub0b4 \uace0\uc555\uc6a9 \uc774\ub3d9\uc804\uc120\uc758 \uc2dc\uc124)\uc81c1\ud56d \uc81c212\uc870(\ud2b9\uace0\uc555 \uc625\ub0b4 \uc804\uae30\uc124\ube44\uc758 \uc2dc\uc124)\uc81c1\ud56d, \uc81c2\ud56d \uc81c220\uc870(\uc625\uce21 \ub610\ub294 \uc625\uc678\uc5d0 \uc2dc\uc124\ud558\ub294 \uc774\ub3d9 \uc804\uc120\uc758 \uc2dc\uc124) \uc81c4\ud56d, \uc81c5\ud56d<\/td><\/tr><tr><td>6.2.10 Conductors and accessories<\/td><td>&#8211;<\/td><\/tr><tr><td>6.2.11 Rotating electrical machines<\/td><td>\uc81c31\uc870(\ud2b9\uace0\uc555\uc6a9 \uae30\uacc4\uae30\uad6c\uc758 \uc2dc\uc124) \uc81c36\uc870(\uace0\uc555\uc6a9 \uae30\uacc4\uae30\uad6c\uc758 \uc2dc\uc124) \uc81c47\uc870(\ubc1c\uc804\uae30 \ub4f1\uc758 \ubcf4\ud638\uc7a5\uce58)\uc81c1\ud56d \uc81c48\uc870(\ud2b9\uace0\uc555\uc6a9 \ubcc0\uc555\uae30\uc758 \ubcf4\ud638\uc7a5\uce58) \uc81c49\uc870(\uc870\uc0c1\uc124\ube44\uc758 \ubcf4\ud638\uc7a5\uce58) \uc81c174\uc870(\uc804\ub3d9\uae30\uc758 \uacfc\ubd80\ud558 \ubcf4\ud638 \uc7a5\uce58\uc758 \uc2dc\uc124)<\/td><\/tr><tr><td>6.2.12 Generating units<\/td><td>\uc81c47\uc870(\ubc1c\uc804\uae30 \ub4f1\uc758 \ubcf4\ud638\uc7a5\uce58)\uc81c1\ud56d \uc81c51\uc870(\uc218\uc18c\ub0c9\uac01\uc2dd \ubc1c\uc804\uae30 \ub4f1\uc758 \uc2dc\uc124) \uc81c55\uc870(\uc0c1\uc8fc \uac10\uc2dc\ub97c \ud558\uc9c0 \uc544\ub2c8\ud558\ub294 \ubc1c\uc804\uc18c\uc758 \uc2dc\uc124)<\/td><\/tr><tr><td>6.2.13 Generating unit main connections<\/td><td>&#8211;<\/td><\/tr><tr><td>6.2.14 Static converters<\/td><td>\uc81c31\uc870(\ud2b9\uace0\uc555\uc6a9 \uae30\uacc4\uae30\uad6c\uc758 \uc2dc\uc124) \uc81c36\uc870(\uace0\uc555\uc6a9 \uae30\uacc4\uae30\uad6c\uc758 \uc2dc\uc124)<\/td><\/tr><tr><td>6.2.15 Fuses<\/td><td>\uc81c31\uc870(\ud2b9\uace0\uc555\uc6a9 \uae30\uacc4\uae30\uad6c\uc758 \uc2dc\uc124) \uc81c35\uc870(\uc544\ud06c\ub97c \ubc1c\uc0dd\ud558\ub294 \uae30\uad6c\uc758 \uc2dc\uc124) \uc81c36\uc870(\uace0\uc555\uc6a9 \uae30\uacc4\uae30\uad6c\uc758 \uc2dc\uc124)<\/td><\/tr><tr><td>6.2.16 Electrical and mechanical interlocking<\/td><td>&#8211;<\/td><\/tr><tr><td>7 Installations<\/td><td>&#8211;<\/td><\/tr><tr><td>7.1 General requirements<\/td><td>&#8211;<\/td><\/tr><tr><td>7.1.1 Circuit arrangement<\/td><td>\uc81c41\uc870(\uc9c0\ub77d\ucc28\ub2e8\uc7a5\uce58 \ub4f1\uc758 \uc2dc\uc124) \uc81c2\ud56d, \uc81c3\ud56d, \uc81c4\ud56d<\/td><\/tr><tr><td>7.1.2 Documentation<\/td><td>&#8211;<\/td><\/tr><tr><td>7.1.3 Transport routes (7.1.3.1\uc744 \uc81c\uc678\ud55c\ub2e4)<\/td><td>&#8211;<\/td><\/tr><tr><td>7.1.4 Aisles and access areas<\/td><td>&#8211;<\/td><\/tr><tr><td>7.1.5 Lighting<\/td><td>&#8211;<\/td><\/tr><tr><td>7.1.7 Labelling<\/td><td>&#8211;<\/td><\/tr><tr><td>7.2 Outdoor installations of open design<\/td><td>&#8211;<\/td><\/tr><tr><td>&nbsp;7.2.1 Protection barrier clearance<\/td><td>&#8211;<\/td><\/tr><tr><td>&nbsp;7.2.2 Protective obstacle clearance<\/td><td><br><\/td><\/tr><tr><td>&nbsp;7.2.4 Minimum height over access areas<\/td><td>&#8211;<\/td><\/tr><tr><td>&nbsp;7.2.6 External fences or walls and access doors<\/td><td>&#8211;<\/td><\/tr><tr><td>7.3 Indoor installations of open design<\/td><td>&#8211;<\/td><\/tr><tr><td>7.4 Installation of prefabricated type-tested switchgear<\/td><td>&#8211;<\/td><\/tr><tr><td>7.4.1 General<\/td><td>&#8211;<\/td><\/tr><tr><td>7.4.2 Additional requirements for gas- insulated metal-enclosed switchgear (7.4.2.2\ub294 \uc81c\uc678\ud55c\ub2e4.)<\/td><td>&#8211;<\/td><\/tr><tr><td>7.6 High voltage\/low voltage prefabricated substations<\/td><td>&#8211;<\/td><\/tr><tr><td>8 Safety measures<\/td><td>&#8211;<\/td><\/tr><tr><td>8.1 General<\/td><td>&#8211;<\/td><\/tr><tr><td>8.2 Protection against direct contact<\/td><td>&#8211;<\/td><\/tr><tr><td>8.2.1 Measures for protection against direct contact<\/td><td>&#8211;<\/td><\/tr><tr><td>8.2.2 Protection requirement (\u203b5, \u203b6)<\/td><td>&#8211;<\/td><\/tr><tr><td>8.3 Means to protect persons in case of indirect contact<\/td><td>&#8211;<\/td><\/tr><tr><td>8.4 Means to protect persons working on electrical installations (8.4.6\uc740 \uc81c\uc678\ud55c\ub2e4.)<\/td><td>&#8211;<\/td><\/tr><tr><td>8.5 Protection from danger resulting from arc fault<\/td><td>&#8211;<\/td><\/tr><tr><td>8.6 Protection against direct lightning strokes<\/td><td>&#8211;<\/td><\/tr><tr><td>8.7 Protection against fire&nbsp;<\/td><td>&#8211;<\/td><\/tr><tr><td>8.7.3 Cables<\/td><td>\uc81c136\uc870(\uc9c0\uc911 \uc804\uc120\ub85c\uc758 \uc2dc\uc124)\uc81c4\ud56d, \uc81c5\ud56d, \uc81c6\ud56d \uc81c141\uc870(\uc9c0\uc911\uc804\uc120\uacfc \uc9c0\uc911 \uc57d\uc804\ub958\uc804\uc120 \ub4f1 \ub610\ub294 \uad00\uacfc\uc758 \uc811\uadfc \ub610\ub294 \uad50\ucc28) \uc81c142\uc870(\uc9c0\uc911\uc804\uc120 \uc0c1\ud638 \uac04\uc758 \uc811\uadfc \ub610\ub294 \uad50\ucc28) \uc81c199\uc870(\uba3c\uc9c0\uac00 \ub9ce\uc740 \uc7a5\uc18c\uc5d0\uc11c\uc758 \uc800\uc555\uc758 \uc2dc\uc124) \uc81c200\uc870(\uac00\uc5f0\uc131 \uac00\uc2a4 \ub4f1\uc774 \uc788\ub294 \uacf3\uc758 \uc800\uc555\uc758 \uc2dc\uc124) \uc81c201\uc870(\uc704\ud5d8\ubb3c \ub4f1\uc774 \uc788\ub294 \uacf3\uc5d0\uc11c\uc758 \uc800\uc555\uc758 \uc2dc\uc124) \uc81c209\uc870(\uace0\uc555 \uc625\ub0b4\ubc30\uc120 \ub4f1\uc758 \uc2dc\uc124) \uc81c2\ud56d \uc81c210\uc870(\uc625\ub0b4 \uace0\uc555\uc6a9 \uc774\ub3d9\uc804\uc120\uc758 \uc2dc\uc124) \uc81c2\ud56d<\/td><\/tr><tr><td>8.8 Protection against leakage of insulating liquid and SF6<\/td><td>&#8211;<\/td><\/tr><tr><td>8.9 Identification and marking(8.9.5\ub294 \uc81c\uc678\ud55c\ub2e4.)<\/td><td>&#8211;<\/td><\/tr><tr><td>9 Protection, control and auxiliary systems<\/td><td>&#8211;<\/td><\/tr><tr><td>9.1 Monitoring and control systems (\u203b2)<\/td><td>\uc81c39\uc870(\uace0\uc555 \ubc0f \ud2b9\uace0\uc555 \uc804\ub85c \uc911\uc758 \uacfc\uc804\ub958\ucc28\ub2e8\uae30\uc758 \uc2dc\uc124)\uc81c3\ud56d, \uc81c4\ud56d \uc81c40\uc870(\uacfc\uc804\ub958\ucc28\ub2e8\uae30\uc758 \uc2dc\uc124 \uc81c\ud55c) \uc81c41\uc870(\uc9c0\ub77d\ucc28\ub2e8\uc7a5\uce58 \ub4f1\uc758 \uc2dc\uc124) \uc81c47\uc870(\ubc1c\uc804\uae30 \ub4f1\uc758 \ubcf4\ud638\uc7a5\uce58)\uc81c1\ud56d \uc81c48\uc870(\ud2b9\uace0\uc555\uc6a9 \ubcc0\uc555\uae30\uc758 \ubcf4\ud638\uc7a5\uce58) \uc81c49\uc870(\uc870\uc0c1\uc124\ube44\uc758 \ubcf4\ud638\uc7a5\uce58) \uc81c55\uc870(\uc0c1\uc8fc \uac10\uc2dc\ub97c \ud558\uc9c0 \uc544\ub2c8\ud558\ub294 \ubc1c\uc804\uc18c\uc758 \uc2dc\uc124) \uc81c56\uc870(\uc0c1\uc8fc \uac10\uc2dc\ub97c \ud558\uc9c0 \uc544\ub2c8\ud558\ub294 \ubcc0\uc804\uc18c\uc758 \uc2dc\uc124)<\/td><\/tr><tr><td>9.2 DC and AC supply circuits<\/td><td>&#8211;<\/td><\/tr><tr><td>9.3 Compressed air systems<\/td><td>\uc81c35\uc870(\uc544\ud06c\ub97c \ubc1c\uc0dd\ud558\ub294 \uae30\uad6c\uc758 \uc2dc\uc124) \uc81c52\uc870(\uac00\uc2a4\uc808\uc5f0\uae30\uae30 \ub4f1\uc758 \uc555\ub825\uc6a9\uae30\uc758 \uc2dc\uc124)<\/td><\/tr><tr><td>9.4 SF6 gas handling plants<\/td><td>&#8211;<\/td><\/tr><tr><td>9.5 Hydrogen handling plants<\/td><td>&#8211;<\/td><\/tr><tr><td>9.6 Basic rules for electromagnetic compatibility of control systems<\/td><td>&#8211;<\/td><\/tr><tr><td>10 Earthing systems<\/td><td>&#8211;<\/td><\/tr><tr><td>10.1 General<\/td><td>&#8211;<\/td><\/tr><tr><td>10.2 Fundamental requirements<\/td><td>&#8211;<\/td><\/tr><tr><td>10.3 Design of earthing systems<\/td><td>\uc81c27\uc870(\uc804\ub85c\uc758 \uc911\uc131\uc810\uc758 \uc811\uc9c0)<\/td><\/tr><tr><td>10.4 Construction of earthing systems<\/td><td>&#8211;<\/td><\/tr><tr><td>10.5 Measurements<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h6>\u203b 1 : \uac00\uacf5 \uc804\uc120\ub85c\ub85c\ubd80\ud130\uc758 \uc804\ud30c \uc7a5\ud574\uc758 \ubc29\uc9c0\uc5d0 \ub300\ud574\uc11c\ub294 \uc81c57\uc870\uc5d0 \ub530\ub97c \uac83.<br>\u203b 2 : \uc9c0\uc9c4\uc5d0 \uc758\ud55c \uc9c4\ub3d9\uc744 \uace0\ub824\ud560 \uac83.<br>\u203b 3 : \ud48d\uc18d\uc5d0 \ub300\ud55c \uc870\uac74\uc740 \uae30\uc220\uae30\uc900 \uc81c33\uc870 \ubc0f \uae30\uc220\uae30\uc900 \uc81c45\uc870\uc5d0 \uc801\ud569\ud560 \uac83.\u00a0<br>\u203b 4 : \uc18c\uc74c\u318d\uc9c4\ub3d9\uaddc\uc81c\ubc95 \ubc0f \ub3d9 \uc2dc\ud589\uaddc\uce59\uc758 \uaddc\uc815\uc5d0 \uc801\ud569\ud560 \uac83.<br>\u203b 5 : \uc0c1\ubd80 \uc774\uaca9\uac70\ub9ac\uc5d0 \ub300\ud574\uc11c\ub294 \uc81c31\uc870\uc81c1\ud56d, \uc81c36\uc870\uc81c1\ud56d \ub610\ub294 \uc81c44\uc870\uc81c5\ud56d\uc5d0 \ub530\ub97c \uac83.<br>\u203b 6 : 7.2.4 \ubc0f 7.2.5\uc758 \ucc38\uc870\uc640 \uad00\ub828\ub418\ub294 \ubd80\ubd84\uc744 \uc81c\uc678\ud55c\ub2e4.<\/h6>\n\n\n\n<h6>\ube44\uace0 1. IEC(International Electrotechnical Commission; \uad6d\uc81c\uc804\uae30\uc704\uc6d0\ud68c) \u00a0<br>  \u00a0\u00a0 \u00a0 2. KS C IEC 61936-1(2007)\uc744 \ucc38\uace0\ud55c\ub2e4.<\/h6>\n\n\n\n<p>\uc804\uae30\uc124\ube44\uae30\uc900 KEC<\/p>\n\n\n\n<p><a href=\"https:\/\/cq4l.com\/kec\/\"><strong>KEC<\/strong><\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec100\/\">100\uacf5\ud1b5<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec110\/\">110\uc124\ube44\uaddc\uc815<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec120\/\">120\uc804\uc120<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec130\/\">130\uc808\uc5f0<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec140\/\">140\uc811\uc9c0<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec150\/\">150\ud53c\ub8b0<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/cq4l.com\/kec\/\"><strong>KEC<\/strong><\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec200\/\">200\uc800\uc555<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec210\/\">210\uc548\uc804<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec220\/\">220\uc120\ub85c<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec230\/\">230\ubc30\uc120<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec240\/\">240\ud2b9\uc218<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec242\/\">242\uc7a5\uc18c<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec242\/#243-%EC%A0%80%EC%95%95-%EC%98%A5%EB%82%B4%EC%A7%81%EB%A5%98-%EC%A0%84%EA%B8%B0%EC%84%A4%EB%B9%84\">243\uc625\ub0b4<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec244\/\">244\ube44\uc0c1\uc804\uc6d0<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/cq4l.com\/kec\/\"><strong>KEC<\/strong><\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec300\/\">300\uace0\uc555<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec310\/\">310\uc548\uc804<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec320\/\">320\uc811\uc9c0<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec330\/\">330\uc120\ub85c<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec340\/\">341\uae30\uacc4<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec342\/\">342\uc625\ub0b4<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec350\/\">350\ubc1c\ubc30\uac1c<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec360\/\">360\ud1b5\uc2e0<\/a><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/cq4l.com\/kec\/\">KEC<\/a><\/strong>\u00a0<a href=\"https:\/\/cq4l.com\/kec400\/\">400\ucca0\ub3c4<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec410\/\">410\uc804\uae30<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec420\/\">420\ubcc0\uc804<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec430\/\">430\uc120\ub85c<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec440\/\">440\ucc28\ub7c9<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec450\/\">450\ubcf4\ud638<\/a>\u00a0<a href=\"https:\/\/cq4l.com\/kec460\/\">460\uc548\uc804<\/a><\/p>\n\n\n\n<p><strong><a rel=\"noreferrer noopener\" href=\"https:\/\/cq4l.com\/kec\/\" target=\"_blank\">KEC<\/a><\/strong>\u00a0<a rel=\"noreferrer noopener\" href=\"https:\/\/cq4l.com\/kec500\/\" target=\"_blank\">500\ud1b5\uce59<\/a>\u00a0<a rel=\"noreferrer noopener\" href=\"https:\/\/cq4l.com\/kec510\/\" target=\"_blank\">510\uc800\uc7a5\uc7a5\uce58<\/a>\u00a0<a rel=\"noreferrer noopener\" href=\"https:\/\/cq4l.com\/kec520\/\" target=\"_blank\">520\ud0dc\uc591\uad11<\/a>\u00a0<a rel=\"noreferrer noopener\" href=\"https:\/\/cq4l.com\/kec530\/\" target=\"_blank\">530\ud48d\ub825<\/a>\u00a0<a rel=\"noreferrer noopener\" href=\"https:\/\/cq4l.com\/kec540\/\" target=\"_blank\">540\uc5f0\ub8cc\uc804\uc9c0<\/a><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\uc804\uae30\uc124\ube44 \uc81c7\uc7a5 \uad6d\uc81c\ud45c\uc900\ub3c4\uc785 \uc81c279\uc870, \uc81c280\uc870, \uc81c279\uc870(1 kV \uc774\ud558 \uc804\uae30\uc124\ube44\uc758 \uc2dc\uc124) \u2460 \uc218\uc6a9 \uc7a5\uc18c\uc5d0 \uc2dc\uc124\ud558\ub294 1kV \uc774\ud558 \uc804\uae30\uc124\ube44\ub294 \ud45c 279-1\uc758 IEC 60364\uc5d0 \ub530\ub77c \uc2dc\uc124\ud560 \uc218 \uc788\ub2e4. \ub2e4\ub9cc, \uc804\uae30\uc0ac\uc5c5\uc790\uc758 \uc804\uae30\uc124\ube44\uc640 \uc9c1\uc811 \uc811\uc18d\ud558\ub294 \uacbd\uc6b0\uc5d0\ub294 \uc804\uae30\uc0ac\uc5c5\uc790\uc758 \uc804\uae30\uacf5\uae09\uacfc \uad00\ub828\ub41c \uc124\ube44\uc758 \uc811\uc9c0\ubc29\uc2dd\uacfc \ud611\uc870\ub97c \uc774\ub8e8\uc5b4\uc57c \ud55c\ub2e4. \u2461 \ub3d9\uc77c\ud55c \uc804\uae30\uc0ac\uc6a9\uc7a5\uc18c\uc5d0\uc11c\ub294 \uc81c1\ud56d\uc758 \uaddc\uc815\uacfc \uc81c3\uc870\ubd80\ud130 \uc81c278\uc870\uae4c\uc9c0\uc758 \uaddc\uc815\uc744 \ud63c\uc6a9\ud558\uc5ec 1kV \uc774\ud558\uc758 \uc804\uae30\uc124\ube44\ub97c \uc2dc\uc124\ud558\uc5ec\uc11c\ub294 \uc544\ub2c8 \ub41c\ub2e4. \ub2e4\ub9cc, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[513,1],"tags":[],"_links":{"self":[{"href":"http:\/\/ftz.myds.me\/wordpress\/wp-json\/wp\/v2\/posts\/12044"}],"collection":[{"href":"http:\/\/ftz.myds.me\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/ftz.myds.me\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/ftz.myds.me\/wordpress\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/ftz.myds.me\/wordpress\/wp-json\/wp\/v2\/comments?post=12044"}],"version-history":[{"count":0,"href":"http:\/\/ftz.myds.me\/wordpress\/wp-json\/wp\/v2\/posts\/12044\/revisions"}],"wp:attachment":[{"href":"http:\/\/ftz.myds.me\/wordpress\/wp-json\/wp\/v2\/media?parent=12044"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/ftz.myds.me\/wordpress\/wp-json\/wp\/v2\/categories?post=12044"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/ftz.myds.me\/wordpress\/wp-json\/wp\/v2\/tags?post=12044"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}